Rose Prairie Drinking Water Treatment

Mountain lake in camera lens

Objectives 

• Toxic and explosive gases (methane and hydrogen sulfide) removal 
• Water treatability analysis  
• Water recovery and brine management

Location: Canada
Capacity: 110 m3/d

Services

• Water chemistry and mass balance modelling
• Root cause analysis 
• Water treatment process scheme and technology screening
• Technology integration modelling
• Feasibility study

Contaminants

• Dissolved and undissolved methane
• Dissolved and undissolved hydrogen sulfide
• Total dissolved solids 
• Organics

Processes

• Aeration 
• Nano filtration 
• Granular activated carbon
• Chlorination